{"product_id":"geyserwise-max-wifi-enabled","title":"Geyserwise Max  - Wifi enabled","description":"\u003cp\u003e\u003cstrong\u003eFor use in pumped solar water heating systems\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSmart Wifi Geyser Controller. Download the Tuya Smart App and manage your geyser from your phone anywhere in the world.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/apps.apple.com\/us\/app\/tuya-smart\/id1034649547\" rel=\"noreferrer noopener\" target=\"_blank\"\u003eDownload For IOS \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.tuya.smart\u0026amp;hl=en_ZA\u0026amp;gl=US\u0026amp;pli=1\" rel=\"noreferrer noopener\" target=\"_blank\"\u003eDownload for Android\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eUsing the app will enable you to:\u003c\/p\u003e\n\u003cul class=\"wp-block-list\"\u003e\n\u003cli\u003eView your geyser temperatures\u003c\/li\u003e\n\u003cli\u003eSet your temperatures\u003c\/li\u003e\n\u003cli\u003eSwitch Your Geyser On And Off from virtually anywhere.\u003c\/li\u003e\n\u003cli\u003eManage Your Geyser like a wifi geyser controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 class=\"wp-block-heading\"\u003eDescription\u003c\/h4\u003e\n\u003cul class=\"wp-block-list\"\u003e\n\u003cli\u003eClear display of water temperature, time, day, heating mode and malfunction conditions.\u003c\/li\u003e\n\u003cli\u003eAuto or manual heating.\u003c\/li\u003e\n\u003cli\u003eEasy temperature setting to your requirements (30 – 75°C) factory default is 55°C.\u003c\/li\u003e\n\u003cli\u003eFour different temperature settings.\u003c\/li\u003e\n\u003cli\u003eDaily programmable timer with four time settings.\u003c\/li\u003e\n\u003cli\u003eError conditions alert by warning code E1 to E7.\u003c\/li\u003e\n\u003cli\u003eElectronic thermostat with mechanical thermal cut-out at 90°C. Please note the cut-out temperature for solar systems expected to reach temperatures above this temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eUse as timer and differential control on 12V or 220V pumped solar\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cb\u003esystem\u003c\/b\u003e.\u003c\/p\u003e\n\u003cul class=\"wp-block-list\"\u003e\n\u003cli\u003eClear display of water temperature, time, day, heating mode and malfunction conditions on solar system and geyser.\u003c\/li\u003e\n\u003cli\u003eAuto or manual heating.\u003c\/li\u003e\n\u003cli\u003eEasy temperature setting to your requirements (30 – 75°C) factory default is 55°C.\u003c\/li\u003e\n\u003cli\u003eFour different temperature settings.\u003c\/li\u003e\n\u003cli\u003eDaily programmable timer with four time settings.\u003c\/li\u003e\n\u003cli\u003eError conditions alert by warning code E1 to E9.\u003c\/li\u003e\n\u003cli\u003eElectronic thermostat with mechanical thermal cut-out at 90°C. Please note the cut-out temperature for systems expected to reach temperatures above this temperature.\u003c\/li\u003e\n\u003cli\u003eDifferential controller 12V and 220V systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 class=\"wp-block-heading\" id=\"Technical_Specifications_Max\"\u003eTechnical Parameters\u003c\/h4\u003e\n\u003cul class=\"wp-block-list\"\u003e\n\u003cli\u003eOperating voltage 230VAC \/ 50HZ.\u003c\/li\u003e\n\u003cli\u003eMain Relay contact rating 30AMP (Max 4KW).\u003c\/li\u003e\n\u003cli\u003eSecondary relays pump and solenoid 5Amp.\u003c\/li\u003e\n\u003cli\u003eOperating voltage range 220V – 250V AC.\u003c\/li\u003e\n\u003cli\u003eEarth leakage protection at 25MA action time = 0,1 second.\u003c\/li\u003e\n\u003cli\u003eTemperature display range 0 – 99°C (“-5” when below -5°C “EA” when above 99°C).\u003c\/li\u003e\n\u003cli\u003eHigh temperature warning above 84°C.\u003c\/li\u003e\n\u003cli\u003eTemperature setting ranges 30 – 75°C (heating water electrically).\u003c\/li\u003e\n\u003cli\u003eHeat failure – when increase at a rate of less than 4°C per hour.\u003c\/li\u003e\n\u003cli\u003eElectronic thermostat with mechanical thermal cut-out at 90°C.\u003c\/li\u003e\n\u003cli\u003eDry heat detection – empty cylinder.\u003c\/li\u003e\n\u003cli\u003eTemperature tolerance ± 2%.\u003c\/li\u003e\n\u003cli\u003eTemperature differential setting 1°C.\u003c\/li\u003e\n\u003cli\u003eSwitching differential 6°C.\u003c\/li\u003e\n\u003cli\u003e2nd temperature probe for solar.\u003c\/li\u003e\n\u003cli\u003eSolar differential 7°C – 15°C. Default is 7°C.\u003c\/li\u003e\n\u003cli\u003eTemperature probe failure detection for both collector and tank.\u003c\/li\u003e\n\u003cli\u003eTemperature probe range for geyser is -30 to + 130°C.\u003c\/li\u003e\n\u003cli\u003eTemperature probe range for collector is -30 to + 260°C.\u003c\/li\u003e\n\u003cli\u003eIsolate both L + N when in off state.\u003c\/li\u003e\n\u003cli\u003eCollector antifreeze protection at 0°C – 10°C. Default is 5°C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Enviruheat","offers":[{"title":"Default Title","offer_id":45963777736945,"sku":null,"price":2948.51,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0732\/6059\/7489\/files\/GeyserwiseMax.png?v=1768912264","url":"https:\/\/www.enviruheat.co.za\/products\/geyserwise-max-wifi-enabled","provider":"Enviruheat","version":"1.0","type":"link"}